1M
!
!
!
!
!
!
!
!
!
Example of use
Functions and their programming
The output contact will close by
pressing the button and open by
releasing the button.
The output contact will close by
pressing the button and open after
the set time interval has elapsed.
The output contact will close by
pressing the button.
The output contact will close by
pressing the button.
The output contact will switch to
the opposite position with each
press of the button. If the contact
was closed, it will open and vice
versa.
The output contact will close by
pressing the button and open after
the set time interval has elapsed.
Button Close Switch off
Impulse relay
Delayed return Delayed start
1x press 2x press 3x press
4x press
5x press 6x press
rogram.
mode
rogram.
mode
rogram.
mode
rogram.
mode
rogram.
mode
rogram.
mode
this is a quick solution for wireless control of appliances into a socket, when the switching socket
is connected between the existing socket and controlled appliance
RFSC-11: single-function design - switch on, switch o
RFSC-61: multifunction design - button switch on/o , impulse relays, delayed return, delayed start programming
and manual control ON/OFF is performed by pressing the button on the front panel of the device
switching output up to 4000 VA
the switched socket may be controlled by up to 32 channels
option of assigning receivers to the RF Control system
LED signaling of device status on the front panel:
- red - status
- green - power indication
option of setting function delayed return, delayed start with time interval from 1 up to 10 hours
produced in three designs of sockets and plugs:
CONTROL ELEMENTS
RF receiver: Switched socket RFSC-11, RFSC-61
EAN code
RFSC-11/F: 8595188145596 (French)
RFSC-11/S: 8595488145619 (Schuko)
RFSC-11/B: 8595188145114 (British)
RFSC-61/F: 8595188145602 (French)
RFSC-61/S: 8595488145626 (Schuko)
RFSC-61/B: 8595188145442 (British)
French Schuko British
CZ, SK, PL, FR HU, DE, RU, AT, RO GB
Button Prog
Supply voltage
indication
Device status
indication
Supply voltage:
Apparent power:
Dissipated power:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. switching power DC:
Mechanical service life:
Electrical service life (AC1):
Controlling
RF command from the transmitter:
Manual control:
Range in open space:
Further data
Operating temperature:
Working position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Dimensions:
Weight:
Related standards:
230 V AC / 50 - 60 Hz
6 VA
0.7 W
+10 %; -15 %
868 MHz
button PROG (ON/OFF)
-15 up to + 50 °C
any *
in a network socket 230 V AC
IP 30
III.
2
60 x 120 x 80 mm
195 g
EN 60669, EN 300 220, EN 301 489
Directives RTTE, NVč.426/2000Sb (directive 1999/ES)
Technical parameters
1x switching (AgSnO
2
)
16 A / AC1
4000 VA / AC1, 384 W / DC
30 A / <3 s
250 V AC1 / 24 V DC
500 mW
3x10
7
0.7x10
5
up to 200 m